Arming

A place can be armed for intruder detection. You group the place's door, window and motion sensors into profiles (“Night”, “Away”, “Perimeter”), and a user or a rule arms a profile. Huntress refuses to arm while one of its sensors is open, and rules can read the armed state and react when a sensor trips: the response is a rule you write, so it can be an incident, an e-mail or a siren.

Not a panelThis is Huntress's own arming. It does not arm or disarm an alarm panel, and the Armed and Disarmed states of the Sensor state condition still follow the arm and disarm events a panel reports. See Alarm panels.

Profiles#

  • A profile belongs to one place and holds that place's open/closed or triggered/clear sensors: doors, windows, motion, glass break and the like. Outputs, analogue sensors and a gas sensor that has a limit are not offered. A sensor can be in several profiles.
  • Several profiles can be armed at the same time, for example a perimeter profile outside and an inside profile while you are at home. The place counts as armed while any of its profiles is.
  • Profiles are created, changed and deleted on the Arming tab of the place by an Owner or Admin. Viewers see them.
  • Deleting a sensor, or moving it to another place, takes it out of its profiles. A place has at most 50 profiles and a profile at most 500 sensors.

Arming and disarming#

Any member of the organisation can arm and disarm on the Arming tab, like operating an ordinary output. A rule arms as itself, and the timeline records who or what did it. A badge on the place's cards, on the dashboard and on the place page shows what is armed.

An open sensor blocks arming#

Arming is refused while any sensor of the profile is open or triggered, or a linked alarm-panel zone is active. The message names the sensors, and the refusal is recorded in the timeline. Close them and arm again.

  • A sensor that is offline, or has never reported a value, does not block: its last value cannot be trusted either way. It is listed as not reporting in the arming event. A profile whose sensors are all offline can therefore be armed. A sensor that has merely been quiet for a while is not offline: without uptime monitoring its last value, such as an open door, still counts.
  • A profile with no sensors cannot be armed.
  • The check reads the stored readings, which can be a fraction of a second behind: a door that opened a moment ago may not block the arm.

Arming anyway#

A profile has the switch Allow arming with open sensors. When it is on, a user who arms with open sensors is asked to confirm, and the open sensors are bypassed until the profile is disarmed: they do not count as guarded, so rules do not treat them as armed, and the arming event names them. A rule arms without being asked, so the switch decides for everyone. A bypass lasts for the whole arming, not until the sensor closes.

Arming an armed profile, or disarming a disarmed one, changes nothing and records nothing. A rule arms or disarms a given profile at most once every 10 seconds.

In rules#

What rules can do
PieceWhat it does
Arm place and Disarm place (actions)Arm or disarm a chosen profile. The profile names its place, so it works in any rule, a schedule trigger included. A refusal is not an error of the rule.
Profile armed (condition)True while a profile is armed, or while it is not. With no profile chosen it asks about the sensor that fired: is it in an armed profile that did not bypass it? A sensor in no profile, such as a camera, asks whether any profile of the place is armed.
Arming change (trigger)Starts when a profile is armed, disarmed, or cannot be armed. Choose the profiles and the changes, or leave them open for all.

A missing profile, one of another organisation, or none chosen makes the condition false either way, and the action does nothing; Huntress never guesses.

Arm at night, disarm in the morning#

Start a rule on a schedule that switches on at 22:00 and give it the action Arm place for the Night profile. Start another when the schedule ends with Disarm place.

Raise an incident when an armed door opens#

Trigger on the door contacts, add the conditions Value threshold above 0 and Profile armed with no profile chosen, and the action Create incident. The value condition matters: an open door reports 1 and a closing door reports 0 from the same sensor, so without it closing the door would start the rule too. Do not filter on the event nature: door and window contacts report the same open/close nature for both. While the profile is disarmed an open door is just a door.

Be told when a scheduled arm did not happen#

The schedule's rule does not retry when a window was open at 22:00. Add a rule with the trigger Arming change, the change Cannot be armed, and Send e-mail: the refusal is an event that rules can hear. The rule that armed is never started by its own change, but other rules are.

In the timeline#

Arming events
EventRecorded when
ProfileArmedA profile was armed, by whom, which open sensors were bypassed and which were not reporting.
ProfileDisarmedA profile was disarmed, or deleted while it was armed.
ArmRefusedArming was refused: open sensors, no sensors, or a rule that could not arm.

They appear in the place's events and in All Events, in the Automation domain.

Behaviour worth knowing#

  • A refused scheduled arm is not retried when the sensor closes.
  • The Profile armed condition reads the arming as it is now; the editor's Test tab replays old events against the current arming.
  • Huntress does not raise an alarm by itself, and has no entry or exit delay: both are rules you build from the pieces above.
  • A rule that is started by an arming change cannot also read an incoming event (a threshold or a sensor type), because there is none.
Rolling backA server that is rolled back to a release older than arming skips the rules that use the new actions, condition or trigger (it logs a warning) instead of failing, and a profile that was armed stays armed. Re-check those rules after a rollback.